- Simple, dry, clean and efficient way of sealing hole Ø 25 mm fire resistant.
- Classification EI90/EW90.
- Applicable in a fire resistant wall of 30, 60 and 90 minutes.
- Applicable in combination with wire/cable in pipe, (data) cable and connection cable up to Ø 22 mm.
- Applicable during the installation process and afterwards.
- Simple, dry, clean and efficient way of sealing hole Ø 25 mm fire resistant.
- Classification EI90/EW90.
- Applicable in a fire resistant wall of 30, 60 and 90 minutes.
- Applicable in combination with wire/cable in pipe, (data) cable and connection cable up to Ø 22 mm.
- Applicable during the installation process and afterwards.
- Smokeproof :Sa and S200.
- Soundproofed.
- Maximum 90 minutes fire resistant in an insulated wall.
- Maximum 60 minutes fire resistant in a non-insulated wall.
- Tested in a non-load-bearing wall construction with 2 x 12,5 mm plasterboard panels on both sides.
- Halogen-free.
- Equipped with 2 conical tube inlets with integrated locking for both 16 and 19 mm tube.
- Firm mounting of the box in the wall thanks to the metal screw plates with 3-fold pitch.
- No gap formation between switchgear and wall due to very thin, solid support edge of the metal fasteners.
- Distance to pipe inlet: 29 mm
- Maximum 90 minutes fire resistant in an insulated wall.
- Maximum 60 minutes fire resistant in a non-insulated wall.
- Tested in a non-load-bearing wall construction with 2 x 12,5 mm plasterboard panels on both sides.
- Halogen-free.
- Equipped with 2 conical tube inlets with integrated locking for both 16 and 19 mm tube.
- Firm mounting of the box in the wall thanks to the metal screw plates with 3-fold pitch.
- No gap formation between switchgear and wall due to very thin, solid support edge of the metal fasteners.
- Distance to pipe inlet: 29 mm
- Maximum 60 minutes fire resistant in an insulated wall.
- Tested in a non-load-bearing wall construction with 2 x 12,5 mm plasterboard panels on both sides.
- Halogen-free.
- Equipped with separate combi spout.
- Equipped with 2 conical tube inlets with integrated locking for both 16 and 19 mm tube.
- Firm mounting of the box in the wall thanks to the metal screw plates with 3-fold pitch.
- No gap formation between switchgear and wall due to very thin, solid support edge of the metal fasteners.
- Maximum 90 minutes fire resistant in an insulated wall.
- Maximum 60 minutes fire resistant in a non-insulated wall.
- Tested in a non-load-bearing wall construction with 2 x 12,5 mm plasterboard panels on both sides.
- Halogen-free.
- Equipped with a detachable combi spout.
- Equipped with 2 conical pipe inlets with integrated lock for both 16 and 19 mm pipe, one of which is closed by a break-out port.
- Firm mounting of the box in the wall thanks to the metal screw plates with 3-fold pitch.
- No gap formation between switchgear and wall due to very thin, solid support edge of the metal fasteners.
- Maximum 90 minutes fire resistant in an insulated wall.
- Maximum 60 minutes fire resistant in a non-insulated wall.
- Tested in a non-load-bearing wall construction with 2 x 12,5 mm plasterboard panels on both sides.
- Halogen-free.
- Fitted with combination nozzles 16/19 mm.
- In combination with sealing cap HWD50L (art. no. AT1065) suitable for airtight applications.
- Standard suitable for sheet thickness 25 mm.
- With bottom outlet.
- Applicable for 'open' walls.
- Sideways fastening by means of HSB-support possible (art. no. AT1052).
- 60 minutes fire-resistant
- Suitable for rachel ceilings and metal stud ceilings.
- Application: thick(er) ceiling tiles (e.g. 2 x 12.5 mm plasterboard).
- 45% more welding space than a traditional square central box.
- 12 combi spouts 16 and 19 mm.
- Equipped with conical tube inlet with tube snapper.
- Screw slots between the pipe entries.
- Screw cams for bottom mounting.
- Clamps: a 3rd hand for rachels 22 mm.
- Suitable for cable entry in combination with KST (art. no. AT1062).
- Associated lids: art. no. AT5010 and art. no. AT5011
- Identification sticker for logbook and project administration fire-resistant transits.
- To be installed next to the fire-resistant penetrations.
- for F30-F90 or EI30-EI90 fire-protection walls
- for wall entries and feed-throughs
- attachment using tried-and-tested FX⁴ metal plate screws
- with integrated sealing inserts
- ensures smoke-tight room separation (seals against cold smoke)
- unlimited building material shelf life
- for F30-F90 or EI30-EI90 fire-protection walls
- attachment using tried-and-tested FX⁴ metal plate screws
- with integrated sealing inserts
- ensures smoke-tight room separation (seals against cold smoke)
- unlimited building material shelf life