Installation 2.0 Cables

Eca - aansluitsnoer voeding 3G2,5 mm, Male - open eind, 5 meter

Eca - aansluitsnoer voeding 3G2,5 mm, Male - open eind, 5 meter
Eca - aansluitsnoer voeding 3G2,5 mm, Male - open eind, 5 meter
  • AT8327.05
  • 8712259548807
  • Suitable for use in hollow spaces
  • Maintenance-free according to EN-IEC 61535
  • Equipped with Attema connectors
Amount Packaging
10 st.
Fire class
Eca
Line function
Power supply general (3x2.5)
Cable type
Line "one plug“
Length (M)
5 m
ETIM article class: Patch cord for plug-in building installation
Number of poles
3
Rated voltage
400 V
Rated current
16 A
Degree of protection (IP)
IP20
Pollution degree
2
Halogen free
No
Colour outer sheath
Black
Reaction-to-fire according to EN 13501-6: Class
Eca
Reaction-to-fire according to EN 13501-6: Smoke production
None
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
None
Reaction-to-fire according to EN 13501-6: Acidity
None
Housing material
Polyamide (PA)
Total length
5000 mm
Rated surge voltage
4 kV
Cable diameter
9.7 - 9.7 mm
Housing colour
Black
Mechanical coding
Yes
Pole codification
L, N, PE
Colour coding/contact insert
Black
RAL-number coding/contact insert
9017
Type of locking
Integrated in plug-in connector
Fire load
2.15 kWh
Contact material
CuZn
Surface treatment contacts
Tinned
Continuity resistance
Type of finished cable
Other
Type side 1
Plug
Type side 2
Free conductor end
Conductor end treatment
Ultrasonic compressed wire ends
Cable type
H05VV-F
Dismantle length
90 mm
Strip length
12 mm
Nominal cross section conductor
2.5 mm²
Insulating piece permanent temperature-resistant
90 °C
Cable permanent temperature-resistant to
60 °C
Max. operating temperature at conductor
50 °C
Additional technical data (ETIM)
Product information

Installation 2.0 Cables

Installation 2.0 is a pluggable installation system based on pre-wired central and cable boxes in combination with prefabricated mounted switching material and a pluggable group box. These components are connected with flexible cables. The installation time is therefore greatly reduced compared to traditional installation, and failure costs are kept to a minimum. Cca cords Fire class Cca cords are available upon request. Contact us for current delivery times.

Installation 2.0

Installation 2.0 is a unique and innovative concept. Thanks to the extremely complete range, you can install 100% pluggable: from distribution box to switching material. All products are assembled according to your wishes, tested and, if desired, delivered per floor or unit to the agreed location and time. Plug in. Assemble. Done! With Install 2.0, you work three times faster on the construction site than with traditional installation. And you also reduce your failure costs by 90%.

Save time and prevent failure costs. Install the Click-mate NXT Distribution Box Plug & Play.

Wide range of pluggable cords, suitable for use in hollow spaces and maintenance-free according to EN-IEC 61535, equipped with Attema connectors.

Easily connect to the pluggable cable boxes equipped with Attema connectors.

Pluggable CW75 Central boxes, applicable in hollow ceiling constructions. Suitable for batten ceilings and metal stud ceilings, equipped with Attema connectors.

Installation 2.0

Installation 2.0 is a unique and innovative concept. Thanks to the extremely complete range, you can install 100% pluggable: from distribution box to switching material. All products are assembled according to your wishes, tested and, if desired, delivered per floor or unit to the agreed location and time. Plug in. Assemble. Done! With Install 2.0, you work three times faster on the construction site than with traditional installation. And you also reduce your failure costs by 90%.

Save time and prevent failure costs. Install the Click-mate NXT Distribution Box Plug & Play.

Wide range of pluggable cords, suitable for use in hollow spaces and maintenance-free according to EN-IEC 61535, equipped with Attema connectors.

Easily connect to the pluggable cable boxes equipped with Attema connectors.

Pluggable CW75 Central boxes, applicable in hollow ceiling constructions. Suitable for batten ceilings and metal stud ceilings, equipped with Attema connectors.

Download
Product data sheet

Eca - aansluitsnoer voeding 3G2,5 mm, Male - open eind, 5...

Article no: AT8327.05

Download