- Wall clips allow 'invisible' attachment of K25 conduit to walls or ceilings.
- A limited degree of change of direction is possible.
- Only suitable for K25.
- The wire clips secure the installed wiring.
- The cable clips secure the installed ICT wiring (max. 2 x UTP, FTP or STP).
- This clip makes the installation of ICT-cabling quick and easy.
- Suitable for K25/P25/Z25 conduit.
- 2-pin with rim earthing.
- 16A / 250V with plug-in contacts for solid conductors.
- Consists of base plate with pre-assembled element, cover and mounting hardware.
- Open inlet for flat duct, no separate inlet piece required. Flat duct inlet on other side can be knocked out.
- Integrated stop on base plate for duct and cover.
- Overlaps duct cover by 5 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Knockout in the base plate for rear inlet of duct Ø 16 mm.
- 2-pin with rim earthing.
- 16A / 250V with plug-in contacts for solid conductors.
- Consists of base plate with pre-assembled element, cover and mounting hardware.
- Open inlet for flat duct, no separate inlet piece required. Flat duct inlet on other side can be knocked out.
- Integrated stop on base plate for duct and cover.
- Overlaps duct cover by 5 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Knockout in the base plate for rear inlet of duct Ø 16 mm.
- 10A / 250V with plug-in contacts for solid conductors.
- Consists of base plate with pre-assembled element, cover, rocker operation and mounting hardware.
- Open inlet for flat duct, no separate inlet piece required. Flat duct inlet on other side can be knocked out.
- Integrated stop on base plate for duct and cover.
- Overlaps duct cover by 5 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Knockout in the base plate for rear inlet of duct Ø 16 mm.
- 10A / 250V with plug-in contacts for solid conductors.
- Consists of base plate with pre-assembled element, cover, rocker operation and mounting hardware.
- Open inlet for flat duct, no separate inlet piece required. Flat duct inlet on other side can be knocked out.
- Integrated stop on base plate for duct and cover.
- Overlaps duct cover by 5 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Knockout in the base plate for rear inlet of duct Ø 16 mm.
- Consists of base plate, cap, Cat 5e RJ45 jack with toolless cutting contacts for data cable connection, transparent mounting plate with simple click installation of RJ45 jack, cover with dust cap and mounting hardware.
- Mounting plate and cover can be rotated for both horizontal and vertical application, so that the RJ45 jack and dust cap are always in the correct position.
- Application possible in combination with K25/P25 or Z25/F25 duct.
- Open inlet for flat duct, no separate inlet piece required. Flat duct inlet on other side can be knocked out.
- Integrated stop on base plate for duct and cover.
- Overlaps duct cover by 5 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Knockout in the base plate for rear inlet of duct Ø 16 mm.
- Consists of base plate, cap, Cat 5e RJ45 jack with toolless cutting contacts for data cable connection, transparent mounting plate with simple click installation of RJ45 jack, cover with dust cap and mounting hardware.
- Mounting plate and cover can be rotated for both horizontal and vertical application, so that the RJ45 jack and dust cap are always in the correct position.
- Application possible in combination with K25/P25 or Z25/F25 duct.
- Open inlet for flat duct, no separate inlet piece required. Flat duct inlet on other side can be knocked out.
- Integrated stop on base plate for duct and cover.
- Overlaps duct cover by 5 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Knockout in the base plate for rear inlet of duct Ø 16 mm.
- Expand with flat duct system while retaining existing single built-in switch hardware.
- Plusrand can be mounted on any single back box with 60 mm pitch.
- Extra long M3 x 30 mm screws supplied for support frame mounting.
- Easy mounting and alignment of support frame on Plusrand.
- Equipped with 1 open inlet for K25/P25/Z25 duct. Inlet on other side can be knocked out.
- Integrated stop for duct and cover.
- Overlaps duct cover by 10 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Expand with flat duct system while retaining existing single built-in switch hardware.
- Plusrand can be mounted on any single back box with 60 mm pitch.
- Extra long M3 x 30 mm screws supplied for support frame mounting.
- Easy mounting and alignment of support frame on Plusrand.
- Equipped with 1 open inlet for K25/P25/Z25 duct. Inlet on other side can be knocked out.
- Integrated stop for duct and cover.
- Overlaps duct cover by 10 mm. Purely right-angled sawing and sawing to size of the cover is not necessary.
- Base plate can be mounted on any wall or ceiling junction box.
- Parker screws for attachment of cover are mounted inside cover to prevent loss.
- Surface-mount domestic switching devices can be mounted on cover.
- Cover includes 1 open lead-in and 11 break-outs for K25/P25/Z25 raceways.